Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technisch erforderlich
Diese Cookies sind für die Grundfunktionen des Shops notwendig.
"Alle Cookies ablehnen" Cookie
"Alle Cookies annehmen" Cookie
Ausgewählter Shop
CSRF-Token
Cookie-Einstellungen
Individuelle Preise
Kunden-Wiedererkennung
Kundenspezifisches Caching
Session
Währungswechsel
Komfortfunktionen
Diese Cookies werden genutzt um das Einkaufserlebnis noch ansprechender zu gestalten, beispielsweise für die Wiedererkennung des Besuchers.
Facebook-Seite in der rechten Blog - Sidebar anzeigen
Merkzettel
Statistik & Tracking
Endgeräteerkennung
Google Tag Manager
Partnerprogramm
Multifunction safety module
BH 5910
- Article number: 0054217
- Type: BH5910.03/00MF2/61 DC24V
Protection of men and machines. more
Product description
Protection of men and machines.
Technical specifications
Width: | 45 mm |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
SIL CL acc. to IEC/EN 62061: | 3 |
Nominal voltage: | DC |
Thermal current Ith max.: | 5 A |
1- / 2-channel: | 1, 2 |
Application: | Emergency stop, Light barrier, Safety gate, Two-hand |
Auxiliary contacts: | Yes |
Cross fault detection: | Yes |
Feedback for external monitoring: | Yes |
Connection: | Pluggable screw terminals |
Safe output contacts, redundant NO contacts: | 3 |
Approvals: | UL |
Type: | BH 5910 |
Downloads
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 - Functions selectable via rotational switches to connect max.:
- 8 E-stop circuits, single channel or
- 4 E-stop circuits, 2-channel or
- 4 light curtains or
- 2 light curtains and 1 E-stop circuit or
- 4 safety gates or
- 2 safety gates and 1 E-stop circuit or
- 4 pairs of 2-hand-buttons or Typ III A according to EN ISO 13851 or
- 2 pairs of 2-hand-buttons Typ III C according to EN ISO 13851 and 1 E-stop circuit - In addition selectable:
- Auto or manual reset (simulation input for gate monitor)
- Continuously monitored feedback circuit to monitor external contactors - Cross fault detection
- Short circuit and broken wire detection
- Outputs:
- 3 NO or 2 NO and 1 NC contacts
- 2 semiconductor outputs short circuit proof and overload protected - Under- and overvoltage detection and signalling
- LED indication for operation (RUN), channel 1/2
- 45 mm width