Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technisch erforderlich
Diese Cookies sind für die Grundfunktionen des Shops notwendig.
"Alle Cookies ablehnen" Cookie
"Alle Cookies annehmen" Cookie
Ausgewählter Shop
CSRF-Token
Cookie-Einstellungen
Individuelle Preise
Kunden-Wiedererkennung
Kundenspezifisches Caching
Session
Währungswechsel
Komfortfunktionen
Diese Cookies werden genutzt um das Einkaufserlebnis noch ansprechender zu gestalten, beispielsweise für die Wiedererkennung des Besuchers.
Facebook-Seite in der rechten Blog - Sidebar anzeigen
Merkzettel
Statistik & Tracking
Endgeräteerkennung
Google Tag Manager
Partnerprogramm
Extension module
UG 6929
- Article number: 0065302
- Type: UG6929.54PS/61 AC/DC24V
If more safety cicuits have to be switched, than a safety module provides, the extension module... more
Product description
If more safety cicuits have to be switched, than a safety module provides, the extension module UG 6929 is used. It offers safe and reliable contact multiplication and re-enforcment for safety modules with monitoring of the feedback circuit. Safe semiconductor outputs can be extended by relay output contacts. The extension module has forcibly guided contacts and can be delivered with different contact arrangements.
Technical specifications
Width: | 22,5 mm |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
SIL CL acc. to IEC/EN 62061: | 3 |
Nominal voltage: | AC, AC/DC |
Thermal current Ith max.: | 8 A |
1- / 2-channel: | 1, 2 |
Connection: | Pluggable screw terminals, Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire |
Output contacts max.: | 1 NC contact, 7 NO contacts |
Approvals: | UL |
Type: | UG 6929 |
Downloads
Advantages
- Safety contact multiplication
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 when connected to a suitable safety module - According to EN 50156-1 for furnaces
- Control with safety semiconductor outputs (light curtain, e-stop) possible
- Redundant and forcibly guided contacts
- Output: max.7 NO or 6 NO contacts / 1 NC contact, 1 NC contact for feedback circuit
- 1- or 2-channel
- Indication
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width: 22.5 mm